6C12
SDHA-SDHE complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-11-01 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.9537 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 52.980, 100.030, 232.130 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 48.890 - 2.150 |
| R-factor | 0.2019 |
| Rwork | 0.199 |
| R-free | 0.25820 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2WDQ and 1X6I |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.392 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0135) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.230 |
| High resolution limit [Å] | 2.150 | 2.150 |
| Number of reflections | 63285 | |
| <I/σ(I)> | 8.6 | |
| Completeness [%] | 93.0 | |
| Redundancy | 4.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 273 | 0.1 M HEPES pH 7.5, 0.2 M MgCl2.6H20, 30% (w/v) PEG 3350 and 40 mM NaF |