6ANA
LL2 Fab in complex with anti-Kappa VHH domain
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | CLSI BEAMLINE 08ID-1 |
| Synchrotron site | CLSI |
| Beamline | 08ID-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2016-09-18 |
| Detector | RAYONIX MX-300 |
| Wavelength(s) | 0.97949 |
| Spacegroup name | P 1 |
| Unit cell lengths | 38.925, 63.682, 68.417 |
| Unit cell angles | 114.28, 96.14, 91.92 |
Refinement procedure
| Resolution | 38.559 - 1.700 |
| R-factor | 0.2154 |
| Rwork | 0.215 |
| R-free | 0.23650 |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.824 |
| Data reduction software | XPREP |
| Data scaling software | XDS |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.12_2829: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 38.559 | 1.720 |
| High resolution limit [Å] | 1.700 | 1.700 |
| Rmerge | 0.051 | 0.362 |
| Rpim | 0.036 | 0.258 |
| Number of reflections | 58574 | |
| <I/σ(I)> | 15.8 | |
| Completeness [%] | 89.6 | |
| Redundancy | 2.7 | |
| CC(1/2) | 0.998 | 0.765 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 298 | 1M lithium chloride 0.1M MES, pH 6.0 |