6AML
Phosphotriesterase variant S8
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2017-05-02 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.9537 |
| Spacegroup name | P 21 21 2 |
| Unit cell lengths | 85.134, 85.811, 88.658 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 42.567 - 1.460 |
| R-factor | 0.1541 |
| Rwork | 0.153 |
| R-free | 0.17490 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4cpc |
| RMSD bond length | 0.019 |
| RMSD bond angle | 1.560 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | MOLREP |
| Refinement software | PHENIX ((1.11.1_2575: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 42.570 | |
| High resolution limit [Å] | 1.460 | 1.460 |
| Number of reflections | 112907 | |
| <I/σ(I)> | 20.4 | |
| Completeness [%] | 99.9 | |
| Redundancy | 13.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 277.15 | 100 mM sodium cacodylate, 10% MPD |