6AL5
COMPLEX BETWEEN CD19 (N138Q MUTANT) AND B43 FAB
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-10-19 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 64.800, 92.350, 146.990 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.000 - 3.000 |
R-factor | 0.19307 |
Rwork | 0.189 |
R-free | 0.26302 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5i15 |
RMSD bond length | 0.006 |
RMSD bond angle | 1.178 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0049) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 3.080 |
High resolution limit [Å] | 3.000 | 3.000 |
Rmerge | 0.083 | 0.496 |
Number of reflections | 18262 | 1285 |
<I/σ(I)> | 18.4 | 3.6 |
Completeness [%] | 99.5 | 96.6 |
Redundancy | 6.4 | 5.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 293 | 0.1 M HEPES PH 7.5, 23% PEG 8000 |