5YWL
SsCR_L211H
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U1 |
Synchrotron site | SSRF |
Beamline | BL17U1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2016-10-06 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.9791 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 47.755, 53.150, 140.033 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 34.432 - 2.098 |
R-factor | 0.2088 |
Rwork | 0.206 |
R-free | 0.26540 |
RMSD bond length | 0.008 |
RMSD bond angle | 1.047 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.8.2_1309) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 34.432 | 2.140 |
High resolution limit [Å] | 2.098 | 2.100 |
Number of reflections | 21187 | |
<I/σ(I)> | 20.9 | |
Completeness [%] | 97.9 | |
Redundancy | 7.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291 | 0.2M lithium sulfate monohydrate, 0.1M Tris hydrochloride (pH 8.5), 30% (w/v) PEG 4000 |