5YSI
SdeA mART-C domain EE/AA NCA complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PHOTON FACTORY BEAMLINE BL-17A |
| Synchrotron site | Photon Factory |
| Beamline | BL-17A |
| Temperature [K] | 193 |
| Detector technology | CCD |
| Collection date | 2017-05-05 |
| Detector | ADSC QUANTUM 270 |
| Wavelength(s) | 1 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 37.867, 75.698, 84.682 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 34.555 - 1.546 |
| R-factor | 0.208 |
| Rwork | 0.204 |
| R-free | 0.24580 |
| Structure solution method | SAD |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.091 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.11.1_2575: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 34.555 | 1.602 |
| High resolution limit [Å] | 1.546 | 1.546 |
| Rmerge | 0.542 | |
| Number of reflections | 36284 | 1754 |
| <I/σ(I)> | 32.37 | |
| Completeness [%] | 99.6 | 97.33 |
| Redundancy | 6.7 | 5.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | PEG400, Tris |