5YPA
p62/SQSTM1 ZZ domain with Lys-peptide
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 5C (4A) |
| Synchrotron site | PAL/PLS |
| Beamline | 5C (4A) |
| Temperature [K] | 173 |
| Detector technology | CCD |
| Collection date | 2015-06-17 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1.2 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 29.085, 43.822, 67.219 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 21.993 - 2.502 |
| R-factor | 0.2167 |
| Rwork | 0.211 |
| R-free | 0.26520 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.982 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | HKL-2000 |
| Refinement software | PHENIX ((1.12_2829: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 21.993 | 2.540 |
| High resolution limit [Å] | 2.502 | 2.500 |
| Number of reflections | 2939 | |
| <I/σ(I)> | 13 | |
| Completeness [%] | 96.1 | |
| Redundancy | 4.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | PEG 8000, CaCl2, HEPES |