5Y9P
Staphylococcus aureus RNase HII
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U1 |
| Synchrotron site | SSRF |
| Beamline | BL17U1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-08-20 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.987 |
| Spacegroup name | P 43 21 2 |
| Unit cell lengths | 61.830, 61.830, 163.260 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 50.000 - 2.200 |
| R-factor | 0.23792 |
| Rwork | 0.236 |
| R-free | 0.28231 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2etj |
| RMSD bond length | 0.016 |
| RMSD bond angle | 1.365 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0103) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 57.820 |
| High resolution limit [Å] | 2.200 |
| Number of reflections | 16871 |
| <I/σ(I)> | 18.7 |
| Completeness [%] | 99.8 |
| Redundancy | 14.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 6 | 291 | 0.15M ammonium sulfate, 0.1M MES, 15%(w/v) PEG 4000 |