5Y9P
Staphylococcus aureus RNase HII
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U1 |
Synchrotron site | SSRF |
Beamline | BL17U1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-08-20 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.987 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 61.830, 61.830, 163.260 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 50.000 - 2.200 |
R-factor | 0.23792 |
Rwork | 0.236 |
R-free | 0.28231 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2etj |
RMSD bond length | 0.016 |
RMSD bond angle | 1.365 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0103) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 57.820 |
High resolution limit [Å] | 2.200 |
Number of reflections | 16871 |
<I/σ(I)> | 18.7 |
Completeness [%] | 99.8 |
Redundancy | 14.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 291 | 0.15M ammonium sulfate, 0.1M MES, 15%(w/v) PEG 4000 |