Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5XAC

CLIR - LC3B

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPHOTON FACTORY BEAMLINE AR-NE3A
Synchrotron sitePhoton Factory
BeamlineAR-NE3A
Temperature [K]100
Detector technologyCCD
Collection date2016-02-18
DetectorADSC QUANTUM 270
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths59.369, 73.641, 68.672
Unit cell angles90.00, 101.36, 90.00
Refinement procedure
Resolution35.338 - 1.701
R-factor0.2122
Rwork0.211
R-free0.24500
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3vtu
RMSD bond length0.004
RMSD bond angle0.670
Data reduction softwareDENZO
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.11.1_2575))
Data quality characteristics
 Overall
Low resolution limit [Å]35.338
High resolution limit [Å]1.700
Number of reflections63531
<I/σ(I)>37.86
Completeness [%]99.7
Redundancy4.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5293PEG 3,350, 0.1M HEPES pH 7.5, 200mM NaCl.