Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

5X41

3.5A resolution structure of a cobalt energy-coupling factor transporter using LCP method-CbiMQO

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNFPSS BEAMLINE BL19U1
Synchrotron siteNFPSS
BeamlineBL19U1
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2015-12-15
DetectorMAR555 FLAT PANEL
Wavelength(s)0.9785
Spacegroup nameP 21 21 21
Unit cell lengths96.159, 135.040, 204.424
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.962 - 3.470
R-factor0.3005
Rwork0.299
R-free0.33530
RMSD bond length0.015
RMSD bond angle3.174
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]3.470
Rmerge0.167
Number of reflections34336
<I/σ(I)>10.3
Completeness [%]100.0
Redundancy10.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1LIPIDIC CUBIC PHASE2930.1M NaCl, 35-48% PEG 400, 0.1M MES, PH 6.5

238582

PDB entries from 2025-07-09

PDB statisticsPDBj update infoContact PDBjnumon