Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2009-10-25 |
Detector | ADSC HF-4M |
Wavelength(s) | 0.97918 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 113.097, 113.097, 64.380 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 16.969 - 3.100 |
R-factor | 0.21467 |
Rwork | 0.212 |
R-free | 0.25774 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3r4d |
RMSD bond length | 0.008 |
RMSD bond angle | 1.528 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 16.969 |
High resolution limit [Å] | 3.098 |
Number of reflections | 8557 |
<I/σ(I)> | 9.15 |
Completeness [%] | 96.3 |
Redundancy | 2.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | Tris-HCl, PEG4000, NaCl |