Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-08-24 |
Detector | RIGAKU SATURN A200 |
Wavelength(s) | 1.5418 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 86.910, 41.010, 49.460 |
Unit cell angles | 90.00, 113.20, 90.00 |
Refinement procedure
Resolution | 26.241 - 2.300 |
R-factor | 0.1355 |
Rwork | 0.132 |
R-free | 0.20180 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1zwo |
RMSD bond length | 0.008 |
RMSD bond angle | 0.921 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 40.000 |
High resolution limit [Å] | 2.300 |
Number of reflections | 7149 |
<I/σ(I)> | 40 |
Completeness [%] | 95.0 |
Redundancy | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 297 | 0.2 M Ammonium acetate pH 7.1 and 16% PEG 3350 |