Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-08-24 |
| Detector | RIGAKU SATURN A200 |
| Wavelength(s) | 1.5418 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 86.910, 41.010, 49.460 |
| Unit cell angles | 90.00, 113.20, 90.00 |
Refinement procedure
| Resolution | 26.241 - 2.300 |
| R-factor | 0.1355 |
| Rwork | 0.132 |
| R-free | 0.20180 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1zwo |
| RMSD bond length | 0.008 |
| RMSD bond angle | 0.921 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 40.000 |
| High resolution limit [Å] | 2.300 |
| Number of reflections | 7149 |
| <I/σ(I)> | 40 |
| Completeness [%] | 95.0 |
| Redundancy | 3.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 297 | 0.2 M Ammonium acetate pH 7.1 and 16% PEG 3350 |