5VF4
Thermus aquaticus variable protein (TaqVP) from diversity-generating retroelements (DGR)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-11-17 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.979 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 155.039, 155.039, 202.394 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 80.814 - 2.810 |
R-factor | 0.1793 |
Rwork | 0.178 |
R-free | 0.22870 |
Structure solution method | SAD |
RMSD bond length | 0.009 |
RMSD bond angle | 1.224 |
Data reduction software | MOSFLM |
Phasing software | SOLVE |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 134.270 |
High resolution limit [Å] | 2.810 |
Number of reflections | 132418 |
<I/σ(I)> | 12.5 |
Completeness [%] | 100.0 |
Redundancy | 7.4 |
CC(1/2) | 0.980 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 15% (w/v) 2-methyl-2,4-pentanediol, 20 mm CaCl2, 100 mM Sodium Acetate (pH 4.6) |