5VAP
Crystal structure of eVP30 C-terminus and eNP peptide
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 19-ID |
| Synchrotron site | APS |
| Beamline | 19-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2015-10-12 |
| Detector | DECTRIS PILATUS3 S 6M |
| Wavelength(s) | 0.9792601 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 48.461, 55.078, 114.621 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 50.000 - 1.850 |
| R-factor | 0.1959 |
| Rwork | 0.194 |
| R-free | 0.23250 |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.351 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-3000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 1.880 |
| High resolution limit [Å] | 1.850 | 5.020 | 1.850 |
| Rmerge | 0.058 | 0.033 | 0.636 |
| Rmeas | 0.066 | 0.037 | 0.710 |
| Rpim | 0.030 | 0.017 | 0.309 |
| Number of reflections | 26341 | ||
| <I/σ(I)> | 11.5 | ||
| Completeness [%] | 99.6 | 95.4 | 100 |
| Redundancy | 4.8 | 4.3 | 4.8 |
| CC(1/2) | 0.997 | 0.804 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 7 | 297 | 0.2 M Potassium phosphate monobasic, 20%PEG3350 |