5UUE
Tetragonal thermolysin cryocooled to 100 K with 50% methanol as cryoprotectant
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SEALED TUBE |
Source details | OXFORD DIFFRACTION ENHANCE ULTRA |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-10-30 |
Detector | OXFORD ONYX CCD |
Wavelength(s) | 1.54 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 96.149, 96.149, 104.800 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.801 - 1.600 |
R-factor | 0.202239463246 |
Rwork | 0.201 |
R-free | 0.23490 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 0.946 |
Data reduction software | CrysalisPro |
Data scaling software | SCALA |
Phasing software | PHENIX |
Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.801 | |
High resolution limit [Å] | 1.600 | 1.600 |
Number of reflections | 121775 | |
<I/σ(I)> | 13.1 | |
Completeness [%] | 98.5 | 93.8 |
Redundancy | 7.3 | 4.9 |
CC(1/2) | 0.998 | 0.178 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 295 | Well: ~2 M AmSO4 Drop: 50 mg/mL protein in 45% DMSO, 0.5 M ZnCl2 |