Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 298 |
Detector technology | IMAGE PLATE |
Collection date | 1995-03-29 |
Detector | RIGAKU |
Wavelength(s) | 1.5418 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 49.320, 72.420, 61.250 |
Unit cell angles | 90.00, 109.50, 90.00 |
Refinement procedure
Resolution | 21.180 - 2.260 |
R-factor | 0.1498 |
Rwork | 0.147 |
R-free | 0.20170 |
Structure solution method | SIRAS |
RMSD bond length | 0.010 |
RMSD bond angle | 1.417 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | MOLREP |
Refinement software | REFMAC (refmac_5.8.0155) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 21.180 |
High resolution limit [Å] | 2.260 |
Rmerge | 0.051 |
Number of reflections | 16950 |
<I/σ(I)> | 2 |
Completeness [%] | 97.0 |
Redundancy | 3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.9 | 294 | 18% PEG 8,000, 0.2 M (NH4)2SO4, 50 mM MES, 5 mM DTT, 0.1 mM NaN3, pH 5.9 |