5UEW

BRD2 Bromodomain2 with A-1360579

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2016-10-08
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.0
Spacegroup nameP 1
Unit cell lengths35.996, 41.601, 45.756
Unit cell angles67.40, 66.90, 74.85
Refinement procedure
Resolution18.270 - 1.830
R-factor0.201
Rwork0.199
R-free0.23800
RMSD bond length0.010
RMSD bond angle0.970
Data reduction softwareXDS (2.11.7)
Data scaling softwareSCALA
Refinement softwareBUSTER (2.11.7)
Data quality characteristics
 Overall
Low resolution limit [Å]39.900
High resolution limit [Å]1.800
Rmerge0.056
Number of reflections18605
<I/σ(I)>6.5
Completeness [%]94.8
Redundancy1.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION277Protein buffer : 10 mM HEPES PH 7.5 100 mM NaCl 5 mM DTT Crystallization : 15 % (v/v) Ethanol Tris PH 7.0