5UBL
A circularly permuted version of PvdQ (cpPvdQ)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 271 |
Detector technology | PIXEL |
Collection date | 2016-06-15 |
Detector | DECTRIS PILATUS3 X 1M |
Wavelength(s) | 0.98 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 121.251, 166.120, 94.260 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 50.990 - 1.800 |
R-factor | 0.1805 |
Rwork | 0.179 |
R-free | 0.20180 |
RMSD bond length | 0.007 |
RMSD bond angle | 0.936 |
Data reduction software | iMOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 67.900 |
High resolution limit [Å] | 1.800 |
Number of reflections | 88115 |
<I/σ(I)> | 8 |
Completeness [%] | 98.0 |
Redundancy | 5.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 300 | 0.05 M Hepes (pH 7.5), 80 mM RbCl, 10% PEG 4000 |