Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5TAC

Conformational Sampling Differences across the Arrhenius Plot Biphasic Break Point at Ambient Temperature in the Enzyme Thermolysin

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RUH3R
Temperature [K]296.3
Detector technologyIMAGE PLATE
Collection date2012-05-01
DetectorRIGAKU RAXIS IV
Wavelength(s)1.54178
Spacegroup nameP 61 2 2
Unit cell lengths93.719, 93.719, 131.208
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution31.973 - 2.040
R-factor0.1382
Rwork0.136
R-free0.18570
RMSD bond length0.018
RMSD bond angle1.274
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwarePHENIX (1.7.3_928)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.110
High resolution limit [Å]2.0402.040
Rmerge0.150
Number of reflections223332166
<I/σ(I)>20.2
Completeness [%]100.099.8
Redundancy168
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.32931.4 M (NH 4 ) 2 SO 4 , 12% glycerol, 100 mM Tris buffer, pH 8.3