Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5T6W

HLA-B*57:01 presenting SSTRGISQLW

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2015-04-12
DetectorADSC QUANTUM 315
Wavelength(s)0.954
Spacegroup nameP 21 21 21
Unit cell lengths50.790, 81.180, 109.790
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution32.637 - 1.900
R-factor0.2139
Rwork0.211
R-free0.26300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2rfx
RMSD bond length0.007
RMSD bond angle1.044
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]32.6372.000
High resolution limit [Å]1.9001.900
Rmerge0.1970.553
Number of reflections36411
<I/σ(I)>4.72.3
Completeness [%]99.699.8
Redundancy3.93.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.629812 -20 % PEG 4000, 0.2 M ammonium acetate and 0.1 M tri-sodium citrate pH 5.6

225946

PDB entries from 2024-10-09