5T2M
mPI3Kd IN COMPLEX WITH 7m
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE ID23-1 |
| Synchrotron site | ESRF |
| Beamline | ID23-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2013-05-13 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.976 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 63.577, 141.782, 219.178 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 59.520 - 2.800 |
| R-factor | 0.23 |
| Rwork | 0.228 |
| R-free | 0.27000 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.008 |
| RMSD bond angle | 0.960 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | MOLREP |
| Refinement software | BUSTER (2.11.6) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 219.180 | 2.950 |
| High resolution limit [Å] | 2.800 | 2.800 |
| Rmerge | 0.170 | 0.672 |
| Number of reflections | 24681 | |
| <I/σ(I)> | 7.4 | 2.2 |
| Completeness [%] | 99.1 | 95.8 |
| Redundancy | 5.8 | 5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 50% ethylene glycol/PEG 8000, 0.1 M carboxylic acids mix, 0.1 M Buffer system 2 pH 7.5 |