5T0Y

2A10 Antibody FAB fragment

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyCCD
Collection date2015-04-16
DetectorADSC QUANTUM 315r
Wavelength(s)1.032900
Spacegroup nameP 43 21 2
Unit cell lengths231.684, 231.684, 81.784
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution39.733 - 3.011
R-factor0.2259
Rwork0.225
R-free0.24670
RMSD bond length0.002
RMSD bond angle0.553
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]39.7333.120
High resolution limit [Å]3.0103.010
Number of reflections44655
<I/σ(I)>10.61.8
Completeness [%]99.999.5
Redundancy14.614.6
CC(1/2)0.703
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.5277.152M Ammonium Sulfate, 0.1 M Bis-Tris, pH 6.5

220472