Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5RD4

PanDDA analysis group deposition -- Endothiapepsin ground state model 26

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsMAX IV BEAMLINE BioMAX
Synchrotron siteMAX IV
BeamlineBioMAX
Temperature [K]100
Detector technologyPIXEL
Collection date2019-03-30
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.827
Spacegroup nameP 1 21 1
Unit cell lengths45.421, 72.722, 52.657
Unit cell angles90.00, 109.21, 90.00
Refinement procedure
Resolution42.930 - 1.180
R-factor0.186
Rwork0.185
R-free0.18599
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.013
RMSD bond angle1.827
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareREFMAC (5.8.0238)
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]42.93050.0001.250
High resolution limit [Å]1.1803.5301.180
Rmerge0.0950.0401.578
Rmeas0.1040.0431.729
Total number of observations620269
Number of reflections9168740268248
<I/σ(I)>1139.361.05
Completeness [%]91.50.9940.483
Redundancy6.4116.052.77
CC(1/2)0.9990.9980.363
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.62900.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000

224201

PDB entries from 2024-08-28

PDB statisticsPDBj update infoContact PDBjnumon