5QTG
T. brucei FPPS in complex with CID 126782062
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID30B |
Synchrotron site | ESRF |
Beamline | ID30B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-11-28 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.967700 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 60.356, 60.356, 344.868 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 35.852 - 2.093 |
R-factor | 0.2744 |
Rwork | 0.273 |
R-free | 0.30710 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | pdbid 4ryp |
Data reduction software | XDS (20180808) |
Data scaling software | Aimless (0.7.4) |
Phasing software | PHASER (2.8.2) |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 57.478 | 2.316 |
High resolution limit [Å] | 2.093 | 2.093 |
Rmerge | 0.158 | 2.066 |
Number of reflections | 15971 | |
<I/σ(I)> | 18.9 | 1.8 |
Completeness [%] | 68.6 | 13.5 |
Redundancy | 37.8 | 30.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 293 | 0.12 M CsCl 12 % w/v PEG 3350, 12 % v/v DMSO |