Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5QTF

T. brucei FPPS in complex with CID 144539

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE MASSIF-1
Synchrotron siteESRF
BeamlineMASSIF-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-06-21
DetectorDECTRIS PILATUS3 2M
Wavelength(s)0.966000
Spacegroup nameP 61 2 2
Unit cell lengths60.623, 60.623, 341.323
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution56.887 - 1.783
R-factor0.2525
Rwork0.250
R-free0.29310
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)pdbid 4ryp
Data reduction softwareXDS (20180808)
Data scaling softwareAimless (0.7.4)
Phasing softwarePHASER (2.8.2)
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]56.8872.010
High resolution limit [Å]1.7831.783
Rmerge0.1252.569
Rmeas0.1202.029
Rpim0.0200.325
Total number of observations811733121699
Number of reflections240543167
<I/σ(I)>20.32.3
Completeness [%]65.011.1
Redundancy36.537.3
CC(1/2)0.9990.985
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP62930.12 M CsCl 12 % w/v PEG 3350, 12 % v/v DMSO

222926

PDB entries from 2024-07-24

PDB statisticsPDBj update infoContact PDBjnumon