5QT1
PanDDA analysis group deposition -- Partial occupancy interpretation of PanDDA event map: SETDB1 in complex with FMOMB000017a
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-10-11 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.92819 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 55.790, 64.050, 70.810 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.860 - 1.580 |
R-factor | 0.1944 |
Rwork | 0.193 |
R-free | 0.21970 |
Structure solution method | FOURIER SYNTHESIS |
Starting model (for MR) | 3dlm |
RMSD bond length | 0.010 |
RMSD bond angle | 1.631 |
Data reduction software | XDS |
Data scaling software | Aimless (0.5.15) |
Phasing software | REFMAC |
Refinement software | REFMAC (5.8.0238) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 43.820 | 43.820 | 1.620 |
High resolution limit [Å] | 1.580 | 7.070 | 1.580 |
Rmerge | 0.073 | 0.027 | 1.497 |
Rmeas | 0.079 | 0.029 | 1.622 |
Rpim | 0.031 | 0.012 | 0.620 |
Total number of observations | 231870 | 2838 | 17237 |
Number of reflections | 35453 | ||
<I/σ(I)> | 14.4 | 52.1 | 1.3 |
Completeness [%] | 99.9 | 99.8 | 99.9 |
Redundancy | 6.5 | 6.1 | 6.7 |
CC(1/2) | 0.999 | 0.999 | 0.555 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 291 | 25% PEG-3350, 0.2M lithium sulfate, 0.1M Bis-tris |