Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5QAW

OXA-48 IN COMPLEX WITH COMPOUND 27

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2016-04-15
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.918409
Spacegroup nameP 21 21 21
Unit cell lengths90.501, 109.053, 124.636
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.700 - 2.200
Rwork0.198
R-free0.23640
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR): 5dtk
RMSD bond length0.003
RMSD bond angle0.576
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.7002.280
High resolution limit [Å]2.2002.200
Rmerge0.1050.680
Rmeas0.1200.780
Number of reflections26270
<I/σ(I)>9.132.05
Completeness [%]99.4
Redundancy4.44.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52980.1 M HEPES pH 7.5, 8-11% PEG 8000 and 4-8% 1-butanol

224004

PDB entries from 2024-08-21

PDB statisticsPDBj update infoContact PDBjnumon