5OXF
An oligomerised bacterial dynamin pair provides a mechanism for the long range sensing and tethering of membranes
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-08-08 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.92819 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 114.717, 228.675, 318.800 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 58.981 - 3.940 |
R-factor | 0.2604 |
Rwork | 0.259 |
R-free | 0.28760 |
Structure solution method | SAD |
RMSD bond length | 0.004 |
RMSD bond angle | 1.029 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.12_2829: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 185.800 | 4.080 |
High resolution limit [Å] | 3.940 | 3.940 |
Number of reflections | 74962 | |
<I/σ(I)> | 14.6 | |
Completeness [%] | 95.5 | |
Redundancy | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293.15 | 0.7-1.0 M succinate pH 7.0 |