5OV7
tubulin - rigosertib complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-09-11 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 1.00000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 104.732, 156.765, 182.629 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.079 - 2.402 |
R-factor | 0.1921 |
Rwork | 0.190 |
R-free | 0.23510 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4i4t |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX ((dev_2863: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.100 | 2.490 |
High resolution limit [Å] | 2.400 | 2.400 |
Rmerge | 0.138 | 2.120 |
Rmeas | 0.149 | 2.229 |
Number of reflections | 116426 | |
<I/σ(I)> | 12.8 | |
Completeness [%] | 99.0 | |
Redundancy | 6.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |