5OSX
Translation initiation factor 4E in complex with m7G(5'S)ppp(5'S)G mRNA 5' cap analog
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-07-25 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.918 |
Spacegroup name | P 1 |
Unit cell lengths | 37.843, 37.855, 145.987 |
Unit cell angles | 86.56, 84.56, 77.05 |
Refinement procedure
Resolution | 48.405 - 1.920 |
R-factor | 0.2259 |
Rwork | 0.224 |
R-free | 0.26890 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1l8b |
RMSD bond length | 0.009 |
RMSD bond angle | 0.900 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.030 |
High resolution limit [Å] | 1.920 | 1.920 |
Rmerge | 0.058 | 0.358 |
Number of reflections | 57473 | 9143 |
<I/σ(I)> | 10.08 | 2.04 |
Completeness [%] | 95.2 | 94 |
Redundancy | 2.43 | 2.34 |
CC(1/2) | 0.997 | 0.822 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 295 | 0.1M BIS-TRIS propane pH 9.0, 20% v/v PEG MME 550 |