5ONK

Native YndL

Experimental procedure
Experimental methodLAUE
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2017-07-10
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.6 - 2.3
Spacegroup nameP 21 21 21
Unit cell lengths38.670, 46.860, 100.070
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution34.200 - 1.030
R-factor0.16726
Rwork0.166
R-free0.18721
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3a9l
RMSD bond length0.028
RMSD bond angle2.457
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0135)
Data quality characteristics
 Overall
Low resolution limit [Å]34.200
High resolution limit [Å]1.030
Number of reflections76651
<I/σ(I)>18.67
Completeness [%]85.0
Redundancy1.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2911 Ammonium sulphate, 0.15 Sodium citrate