5O2L
Myosin VI motor domain in the Pre-Transition State
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-11-03 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.9800 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 72.340, 83.830, 177.660 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 22.180 - 2.200 |
R-factor | 0.1844 |
Rwork | 0.182 |
R-free | 0.22680 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2v26 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.060 |
Data reduction software | XDS |
Phasing software | PHASER |
Refinement software | BUSTER (2.11.5) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 2.260 |
High resolution limit [Å] | 2.200 | 2.200 |
Number of reflections | 55469 | |
<I/σ(I)> | 15.57 | 1.29 |
Completeness [%] | 99.6 | |
Redundancy | 5.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 277 | 7% polyethylene glycol [PEG] 8000, 50 mM TRIS, pH 7.5, 1 mM TCEP, 15% glycerol |