Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5NMZ

human Neurturin (97-197)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2016-10-04
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97625
Spacegroup nameP 1
Unit cell lengths31.433, 50.794, 53.642
Unit cell angles76.42, 89.33, 94.74
Refinement procedure
Resolution52.120 - 1.600
R-factor0.232
Rwork0.231
R-free0.26400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5mr9
RMSD bond length0.010
RMSD bond angle1.050
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwareBUSTER (2.11.7)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]52.1201.660
High resolution limit [Å]1.6001.600
Number of reflections37888
<I/σ(I)>9.781.93
Completeness [%]89.890.1
Redundancy1.81.8
CC(1/2)0.9980.838
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2933 M Na formate, 0.1 M Bis Tris pH 6

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon