5NIW
Glucose oxydase mutant A2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | ENRAF-NONIUS FR591 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2012-10-18 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.54179 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 128.100, 128.100, 77.650 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 110.940 - 1.800 |
R-factor | 0.15583 |
Rwork | 0.154 |
R-free | 0.19089 |
RMSD bond length | 0.023 |
RMSD bond angle | 2.206 |
Data reduction software | iMOSFLM |
Data scaling software | SCALA |
Phasing software | REFMAC |
Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 41.930 |
High resolution limit [Å] | 1.790 |
Number of reflections | 67817 |
<I/σ(I)> | 12.1 |
Completeness [%] | 98.3 |
Redundancy | 11.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 280 | 100 mM HEPES 45% v/v dioxane |