5NIO
EthR complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-03-01 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9174 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 120.083, 120.083, 33.659 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 84.910 - 1.400 |
R-factor | 0.18214 |
Rwork | 0.181 |
R-free | 0.20498 |
RMSD bond length | 0.017 |
RMSD bond angle | 1.682 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0135) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 84.910 | 1.500 |
High resolution limit [Å] | 1.400 | 1.400 |
Rmerge | 0.034 | 0.400 |
Number of reflections | 48919 | 16586 |
<I/σ(I)> | 22.6 | |
Completeness [%] | 99.2 | 96.2 |
Redundancy | 5.4 | 4.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | MES buffer, 1.4-1.6 M AS |