5MX5
Mouse PA28alpha-beta
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-04-06 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 126.090, 137.380, 136.420 |
Unit cell angles | 90.00, 104.44, 90.00 |
Refinement procedure
Resolution | 15.000 - 2.900 |
R-factor | 0.24453 |
Rwork | 0.243 |
R-free | 0.27226 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5msj |
RMSD bond length | 0.007 |
RMSD bond angle | 0.926 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 3.000 |
High resolution limit [Å] | 2.900 | 2.900 |
Rmerge | 0.059 | 0.532 |
Number of reflections | 96305 | |
<I/σ(I)> | 12.1 | 2.3 |
Completeness [%] | 96.4 | 92.8 |
Redundancy | 2.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 277 | 0.2 M KH2PO4, 9 % PEG3350 |