5MWT
Galectin-1 in Complex with Ligand JB97
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID30B |
Synchrotron site | ESRF |
Beamline | ID30B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-11-10 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.9763 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 43.290, 58.250, 111.240 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 51.603 - 1.711 |
R-factor | 0.206 |
Rwork | 0.205 |
R-free | 0.23220 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 0.739 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (dev_2443) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 60.000 |
High resolution limit [Å] | 1.711 |
Number of reflections | 30672 |
<I/σ(I)> | 9.9 |
Completeness [%] | 98.0 |
Redundancy | 3.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | 1.5 M AMMONIUM SULFATE, PH 7.5, |