Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5MPM

SERCA2a from pig heart

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]77
Detector technologyPIXEL
Collection date2014-09-20
DetectorDECTRIS PILATUS 6M
Wavelength(s)1
Spacegroup nameP 1 21 1
Unit cell lengths53.349, 253.287, 64.981
Unit cell angles90.00, 100.86, 90.00
Refinement procedure
Resolution63.320 - 3.300
R-factor0.2083
Rwork0.204
R-free0.25790
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3fgo
RMSD bond length0.005
RMSD bond angle0.431
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.10_2152: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]63.3203.350
High resolution limit [Å]3.3003.300
Rmerge0.130
Rmeas0.155
Rpim0.082
Number of reflections25135
<I/σ(I)>7.1
Completeness [%]99.099
Redundancy3.43.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.8292.1580 mM KCl, 15 mM MgCl2, 2 mM EGTA, 10 mM NaF, 200 uM CPA

224931

PDB entries from 2024-09-11

PDB statisticsPDBj update infoContact PDBjnumon