5MPM
SERCA2a from pig heart
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 77 |
Detector technology | PIXEL |
Collection date | 2014-09-20 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 53.349, 253.287, 64.981 |
Unit cell angles | 90.00, 100.86, 90.00 |
Refinement procedure
Resolution | 63.320 - 3.300 |
R-factor | 0.2083 |
Rwork | 0.204 |
R-free | 0.25790 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3fgo |
RMSD bond length | 0.005 |
RMSD bond angle | 0.431 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.10_2152: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 63.320 | 3.350 |
High resolution limit [Å] | 3.300 | 3.300 |
Rmerge | 0.130 | |
Rmeas | 0.155 | |
Rpim | 0.082 | |
Number of reflections | 25135 | |
<I/σ(I)> | 7.1 | |
Completeness [%] | 99.0 | 99 |
Redundancy | 3.4 | 3.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.8 | 292.15 | 80 mM KCl, 15 mM MgCl2, 2 mM EGTA, 10 mM NaF, 200 uM CPA |