5MA8
GFP-binding DARPin 3G124nc
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-09-08 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1.00002 |
Spacegroup name | P 41 |
Unit cell lengths | 62.140, 62.140, 213.250 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.940 - 2.350 |
R-factor | 0.1916 |
Rwork | 0.189 |
R-free | 0.23580 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.004 |
RMSD bond angle | 0.890 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 43.940 |
High resolution limit [Å] | 2.350 |
Number of reflections | 33548 |
<I/σ(I)> | 22.33 |
Completeness [%] | 99.9 |
Redundancy | 13.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.3 M Sodium Acetate. 0.1M TRIS (HOAc) pH 7.5, 25% PEG 2K MME |