Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5MA8

GFP-binding DARPin 3G124nc

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2014-09-08
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.00002
Spacegroup nameP 41
Unit cell lengths62.140, 62.140, 213.250
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution43.940 - 2.350
R-factor0.1916
Rwork0.189
R-free0.23580
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.004
RMSD bond angle0.890
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 Overall
Low resolution limit [Å]43.940
High resolution limit [Å]2.350
Number of reflections33548
<I/σ(I)>22.33
Completeness [%]99.9
Redundancy13.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2770.3 M Sodium Acetate. 0.1M TRIS (HOAc) pH 7.5, 25% PEG 2K MME

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon