5M9P
Human angiogenin ALS variant T80S
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-06-30 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9793 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 82.425, 37.335, 42.760 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 42.760 - 1.800 |
R-factor | 0.24195 |
Rwork | 0.238 |
R-free | 0.28522 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1ang |
RMSD bond length | 0.011 |
RMSD bond angle | 1.458 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.800 | 1.840 |
High resolution limit [Å] | 1.800 | 1.800 |
Number of reflections | 12236 | |
<I/σ(I)> | 9 | |
Completeness [%] | 95.7 | 77.9 |
Redundancy | 6.4 | 3.1 |
CC(1/2) | 0.984 | 0.650 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.5 | 289 | 0.2 M ammonium sulphate 0.1 M bis-tris propane 25% PEG 3350 |