Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5LH6

High dose Thaumatin - 360-400 ms.

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, EMBL c/o DESY BEAMLINE P14 (MX2)
Synchrotron sitePETRA III, EMBL c/o DESY
BeamlineP14 (MX2)
Temperature [K]296
Detector technologyPIXEL
Collection date2015-10-24
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.96863
Spacegroup nameP 41 21 2
Unit cell lengths58.490, 58.490, 151.770
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.950 - 2.160
R-factor0.1717
Rwork0.170
R-free0.23600
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1lr2
RMSD bond length0.019
RMSD bond angle2.080
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0131)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0002.230
High resolution limit [Å]2.1502.150
Rmerge0.1770.800
Number of reflections13435
<I/σ(I)>6.112.34
Completeness [%]91.1
Redundancy3.15
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.52931.3 M sodium tartrate and 50 mM Tris, pH 6.8

219140

PDB entries from 2024-05-01

PDB statisticsPDBj update infoContact PDBjnumon