5LH5

High dose Thaumatin - 40-80 ms.

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, EMBL c/o DESY BEAMLINE P14 (MX2)
Synchrotron sitePETRA III, EMBL c/o DESY
BeamlineP14 (MX2)
Temperature [K]296
Detector technologyPIXEL
Collection date2015-10-24
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.96863
Spacegroup nameP 41 21 2
Unit cell lengths58.420, 58.420, 151.590
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.930 - 1.690
R-factor0.1764
Rwork0.176
R-free0.20120
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1lr2
RMSD bond length0.025
RMSD bond angle2.634
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0131)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0001.750
High resolution limit [Å]1.6901.690
Rmerge0.1140.720
Number of reflections30580
<I/σ(I)>7.1
Completeness [%]92.9
Redundancy3.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.52931.3 M sodium tartrate and 50 mM Tris, pH 6.8

227111