Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5KY7

mouse POFUT1 in complex with O-glucosylated EGF(+) and GDP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyCCD
Collection date2013-12-11
DetectorRAYONIX MX-300
Wavelength(s)0.97949
Spacegroup nameP 21 21 21
Unit cell lengths51.890, 66.440, 108.360
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.801 - 1.600
R-factor0.1964
Rwork0.195
R-free0.21570
RMSD bond length0.005
RMSD bond angle1.128
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.660
High resolution limit [Å]1.6001.600
Rmerge0.0640.805
Number of reflections49185
<I/σ(I)>13.52.2
Completeness [%]98.097
Redundancy5.75.9
CC(1/2)0.9980.765
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.529520% PEG2000 MME, 50 mM Tris pH 8.5

224931

PDB entries from 2024-09-11

PDB statisticsPDBj update infoContact PDBjnumon