5KY5
mouse POFUT1 in complex with EGF(+) and GDP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CLSI BEAMLINE 08ID-1 |
Synchrotron site | CLSI |
Beamline | 08ID-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-12-11 |
Detector | RAYONIX MX-300 |
Wavelength(s) | 0.97949 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 52.080, 67.030, 111.100 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.156 - 1.500 |
R-factor | 0.1583 |
Rwork | 0.158 |
R-free | 0.17280 |
RMSD bond length | 0.009 |
RMSD bond angle | 1.118 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (dev_2341) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.550 |
High resolution limit [Å] | 1.500 | 1.500 |
Rmerge | 0.109 | 1.092 |
Number of reflections | 63046 | |
<I/σ(I)> | 9.5 | 1.7 |
Completeness [%] | 100.0 | 100 |
Redundancy | 7.3 | 7.3 |
CC(1/2) | 0.994 | 0.696 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 295 | 20% PEG2000 MME, 50 mM Tris pH 8.5 |