5KXH
mouse POFUT1 in complex with mouse Factor VII EGF1 and GDP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CLSI BEAMLINE 08ID-1 |
Synchrotron site | CLSI |
Beamline | 08ID-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-04-01 |
Detector | RAYONIX MX-300 |
Wavelength(s) | 0.97949 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 51.970, 66.540, 110.640 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.039 - 1.330 |
R-factor | 0.1529 |
Rwork | 0.152 |
R-free | 0.16970 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.901 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.039 | 1.380 |
High resolution limit [Å] | 1.328 | 1.330 |
Rmerge | 0.107 | 1.024 |
Number of reflections | 87243 | |
<I/σ(I)> | 9.2 | 1.2 |
Completeness [%] | 98.0 | 87 |
Redundancy | 7.1 | 5.7 |
CC(1/2) | 0.995 | 0.467 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 295 | 20% PEG 2000 MME 50mM Tris 8.5 |