5KW4

T. danielli thaumatin at 278K, Data set 2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL14-1
Synchrotron siteSSRL
BeamlineBL14-1
Temperature [K]278
Detector technologyCCD
Collection date2014-06-13
DetectorMARMOSAIC 325 mm CCD
Wavelength(s)1.21549
Spacegroup nameP 41 21 2
Unit cell lengths58.659, 58.659, 151.574
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution37.894 - 1.550
R-factor0.1466
Rwork0.145
R-free0.18170
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1rqw
RMSD bond length0.019
RMSD bond angle2.051
Data reduction softwareXDS
Data scaling softwareSCALA (3.3.20)
Refinement softwareREFMAC (5.8.0151)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]37.89437.8941.630
High resolution limit [Å]1.5504.9001.550
Rmerge0.0390.713
Rmeas0.1170.0490.961
Rpim0.0690.0290.638
Total number of observations7172227463069
Number of reflections31960
<I/σ(I)>6.716.60.9
Completeness [%]82.089.842.6
Redundancy2.22.21.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.3291CRYSTALS WERE GROWN BY MIXING EQUAL VOLUMES OF WELL SOLUTION (0.9 M SODIUM/POTASSIUM TARTRATE, 0.2 M AMMONIUM SULFATE, 15% GLYCEROL, 25% PEG 8000, 100 MM HEPES PH 7.3) AND PROTEIN (35 MG/ML) IN THE SITTING DROP FORMAT.