5KW0

T. danielli thaumatin at 100K, Data set 5

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL14-1
Synchrotron siteSSRL
BeamlineBL14-1
Temperature [K]100
Detector technologyCCD
Collection date2014-06-13
DetectorMARMOSAIC 325 mm CCD
Wavelength(s)1.21549
Spacegroup nameP 41 21 2
Unit cell lengths57.814, 57.814, 151.200
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution31.749 - 1.594
R-factor0.1749
Rwork0.173
R-free0.21170
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1rqw
RMSD bond length0.019
RMSD bond angle2.012
Data reduction softwareXDS
Data scaling softwareSCALA (3.3.20)
Refinement softwareREFMAC (5.8.0151)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]31.74931.7491.680
High resolution limit [Å]1.5935.0401.593
Rmerge0.0223.129
Rmeas0.0680.0263.720
Rpim0.0330.0131.962
Total number of observations142905475515928
Number of reflections34950
<I/σ(I)>11.143.20.4
Completeness [%]99.098.494.5
Redundancy4.13.83.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.3291CRYSTALS WERE GROWN BY MIXING EQUAL VOLUMES OF WELL SOLUTION (0.9 M SODIUM/POTASSIUM TARTRATE, 0.2 M AMMONIUM SULFATE, 15% GLYCEROL, 25% PEG 8000, 100 MM HEPES PH 7.3) AND PROTEIN (35 MG/ML) IN THE SITTING DROP FORMAT.

218500

PDB entries from 2024-04-17