5KMT
CTX-M9 mutant L48A
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-BM |
Synchrotron site | APS |
Beamline | 22-BM |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-10-03 |
Detector | MAR CCD 165 mm |
Wavelength(s) | 1.0 |
Spacegroup name | P 32 |
Unit cell lengths | 41.788, 41.788, 232.401 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 36.220 - 1.700 |
R-factor | 0.19543 |
Rwork | 0.194 |
R-free | 0.21607 |
RMSD bond length | 0.012 |
RMSD bond angle | 1.588 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 77.470 |
High resolution limit [Å] | 1.700 |
Number of reflections | 47330 |
<I/σ(I)> | 26.8 |
Completeness [%] | 94.6 |
Redundancy | 8.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.2 | 294 | 1.2 M potassium phosphate |