5JXC
SynGAP Coiled-coil trimer
Experimental procedure
| Experimental method | MAD |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U |
| Synchrotron site | SSRF |
| Beamline | BL17U |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2013-03-24 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.97886 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 28.803, 236.664, 42.207 |
| Unit cell angles | 90.00, 96.92, 90.00 |
Refinement procedure
| Resolution | 39.497 - 2.500 |
| R-factor | 0.2271 |
| Rwork | 0.223 |
| R-free | 0.30700 |
| Structure solution method | MAD |
| RMSD bond length | 0.008 |
| RMSD bond angle | 0.969 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX (1.10_2155) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.540 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Number of reflections | 19240 | |
| <I/σ(I)> | 22.8 | |
| Completeness [%] | 99.7 | |
| Redundancy | 3.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 289 | 0.1M HEPES sodium pH 7.5, 0.1M L-proline, 20% w/v Polyethylene glycol 1500 |