Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

5JTJ

USP7CD-CTP in complex with Ubiquitin

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]170
Detector technologyCCD
Collection date2015-03-18
DetectorRAYONIX MX300-HS
Wavelength(s)1.0
Spacegroup nameP 62 2 2
Unit cell lengths148.060, 148.060, 179.950
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution74.030 - 3.321
R-factor0.1921
Rwork0.191
R-free0.20880
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1nbf
RMSD bond length0.009
RMSD bond angle0.960
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]74.030179.9463.332
High resolution limit [Å]3.32115.4103.321
Rmerge0.1850.0571.881
Rmeas0.190
Rpim0.041
Total number of observations377723
Number of reflections17846
<I/σ(I)>18.1
Completeness [%]100.010099.5
Redundancy21.213.421.8
CC(1/2)0.999
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP62920.05 M Calcium chloride, 0.1 M MES pH 6.0 and 45% PEG 200

248335

PDB entries from 2026-01-28